Centek CT-65H13

SILENCE AND PRODUCTION SPLIT-SYSTEM

 

Air conditioner (split system) Centek CT-65H13 is fixed on the wall and is suitable for rooms up to 38 m². It works in 5 modes, and in addition to heating and cooling, it allows you to dehumidify the air and work in ventilation mode. Thanks to the turbo mode, the device is able to heat or cool the room very quickly, operating at maximum power. If there is a power failure or an emergency shutdown, the device restores the previous mode of operation.
When the iFEEL function is activated, the Centek CT-65H13 split system is able to select the temperature automatically. The sensor built into the remote control is used to measure the room temperature. Therefore, the device will strive to obtain the optimal temperature regime in the area where the remote control is located. A useful option will be the detection of breakdowns by the system. To alert the user, the device uses error codes that appear on the display. Knowing the breakdown, the specialist will be able to repair the device faster.

  • COOLING  
    Production of BTE / Wt 13000/3800
    Nom. power VT 990
    Nom. talk A 4.7
    EER 3.7
    HEATING  
    Production of BTE / Wt 13000/3900
    Nom. power VT 940
    Nom. talk A 4.2
    COP 3.9
    GENERAL  
    Power supply V/Hz 220 - 240/ ~ 50
    Max. entrance. Power, W 1300
    Air circulation (m3/h) 650
    Compressor GMCC
    Refrigerant R410A
    Energy efficiency class A
    INDOOR UNIT  
    Noise level (indoor unit) dB(A) 26
    Dimensions (WxDxH) mm 788*198*292
    Net weight kg 9
    OUTDOOR UNIT  
    Noise level (outdoor unit) dB(A) 48
    Dimensions (WxDxH) mm 730*285*545
    Net weight kg 28
    Minimum recommended trace length required for efficient operation 2.5 m.
    Connection pipe diameter (liquid/gas) 6,35 / 12,7
    Permissible route length 25 m.
    Maximum height difference 12 m.
    ADDITIONAL INFORMATION  
    Waterproofing class (internal/external block) IP IPX4/ IPX4
    Electrical protection class (internal / external unit) Class I/I
    Operating temperature range (cooling/heating) oC +16...+49 / -7...+26
    Cooling/Heating/Dehumidifying/Ventilation
    Auto restart
    Antifungal function
    Auto defrost
    Self-cleaning
    Freon leakage protection function
    Turbo mode
    iFeel function
    Self-diagnosis
    Auto Restart
    Defrost
  • Instruction Russian
    Catalog Russian

     