Robur Gitié AHAY
Trivalent integrated outdoor unit with absorption heat pump powered by renewable energy from gas and air and condensing boiler.
For highly efficient heating and hot water up to 80°C.
Gitié provides 2 services:
- highly efficient heating
- hot water production up to 80°C
Advantages
- Integrated, pre-assembled and custom built from the factory, Gitié is a complete turnkey system. This can facilitate proper installation, avoiding the complexities of integration in the field of solar thermal systems.
- Gitié can offer a cost-effective solution using renewable energy from the air, replacing the "boiler + solar system".For every kW of natural gas equivalent used, Gitié adds 0.5 kW of free renewable energy, available 24 hours a day.
- Gitié has an average seasonal heating efficiency of 158% (GUE - Gas Utilization Efficiency) thanks to the use of renewable energy sources.
- Gitié capital costs are convenient and provide savings of up to 40% in operating costs compared to similar solutions.
- Complies with future regulations for renewable energy and emission reductions.
Available in standard and quiet versions, 2-pipe and 4-pipe, with or without circulation pumps.
- Ideal for residential, industrial, commercial and hospitality applications.
- Suitable for both new and existing buildings as it is suitable for heating systems with low temperature (radiant heating or fan coil units) or high temperature (radiators) distribution systems.
- Outdoor installation.
Energy class ErP (operating at 55°C): A++
Heating output - gas absorption heat pump (A7 / W35) (1): 41.3 kW
G.U.E. gas efficiency - gas absorption heat pump (A7 / W35) (2): 164%
Thermal output - condensing boiler (water 80/60 ° C): 34.4 kW
Efficiency - condensing boiler (50/30 °C): 104.6%
Maximum heating/DHW outlet temperature: 65/80°C
Rated electricity consumption (3) (4) - standard version kW 1.02
Rated power consumption (3) (4) - low noise version - max. / Min. Speed: 0.95 / 0.68kW
Sound pressure Lp at 5 meters (5) - free field, front, directivity factor 2 - standard version: dB(A) 60.1
Sound pressure Lp at 5 meters (5) - free field, front, direction factor 2 - low noise version - max. / Min. Fan speed: dB(A) 53.3 / 50.3
(1) Rated conditions according to EN 12309-2.
(2) Equivalent to COP 4.10 with an energy conversion factor of 2.5.
(3) Tolerance ± 10% depending on electrical voltage and motor consumption.
(4) Version with circulation pumps: 240W optional.
(5) Sound power levels measured in accordance with EN ISO 9614.Final user Literature
ISO 9001 certificate | All products
German English Italian Product brochure | All Absorption products
German English Installation, use and maintenance manual | All Abso products
Direct Digital Controller (DDC)
German English Italian Russian Installation, use and maintenance manual | All Absorption products
Roburbox100 - Plant Control Interface - Application manual
German English French Italian Installation, use and maintenance manual | All Absorption products
Roburbox100 - Plant Control Interface - Installation and use manual
German English French Italian Installation, use and maintenance manual | Gitié AHAY
German English French Italian Installation, use and maintenance manual | Gitié AHAY
Great Britain market
English CE certificate | Gitié ACAY, Gitié AHAY, Gitié ARAY
German English Italian Declaration of Conformity | Gitié ACAY, Gitié AHAY, Gitié ARAY
English Company profile | All the products
English Italian Professional user literature
PED certificate | All Absorption products
German English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section A - Definitions and general concepts
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section B - Index
English Italian Design manual | Gitié AHAY
Section B07 - Gitiè AHAY
English Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01 - Index - Suggestions for designing with the Robur units
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.01 - Sizing criteria
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.02 - Preassembled groups
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.03 - Installation criteria
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.04 - Plumbing design
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.05 - Circulating pumps
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.06 - System water quality
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.07 - Antifreeze protection
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.08 - Buffer tank and hydraulic separator
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.09 - Fuel gas supply
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.10 - Flue gas collection
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.11 - Electrical design
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.12 - Controls
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.13 - DHW production
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.15 - Acoustic issues
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.16 - First start-up
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.17 - Normal operation
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C01.18 - Maintenance
English Italian Design manual | GAHP A, Gitié ACAY, GA ACF, GAHP AR, GAHP GS, GAHP WS, Gitié AHAY, Gitié ARAY, GA ACF HR, GA ACF TK, GA ACF HT, GA ACF LB, Condensing boiler AY
Section C02.01 - Flow balancing
English Italian