Vaillant turboTEC pro VUW 242 / 5-3 dual-circuit gas boiler
Turbocharged wall-mounted and double-circuit gas boiler
Integrated secondary heat exchanger
Possibility of setting to partial power in heating mode
Advanced electronic control system
SKU 10015321 Device name VUW 242/5-3 Useful thermal power range, kW 8.0-24.9 Expansion tank volume, l 6 Rated heat load, kW 26,7 Hot water flow range, l/min. * 1.5-11.5 Dimensions, mm H W D 800 440 338 Gas connection G 1/2” Chimney 60/100 mm Heating circuit connection G 3/4” Water connection G 3/4” Notes: * When heated ΔТ=30 K
- Gas wall-mounted double-circuit boiler with built-in domestic hot water preparation
- The power of the device is regulated by a modulating burner
- Hot water temperature control
- Automatic switching to the mode of preparation of domestic hot water at its consumption from 1.5 l / min. and power control of the device depending on the flow rate and temperature of the heated water
- Forced evacuation of combustion products through a certified chimney/air duct system (for turboTEC pro)
Equipment
- LCD display with backlight, push-button control
- Internal software for status monitoring, parameter setting and troubleshooting
- Built-in flow plate heat exchanger for water heating
- Built-in circulation pump, closed expansion tank, automatic air vent, automatic adjustable bypass valve, safety valve, motorized priority diverter valve
- "Intelligent" pressure control in the heating system
- Copper primary heat exchanger with average efficiency >= 91%
- Chrome nickel steel burner
- Permanent frost protection
- Protection against jamming of the pump and three-way valve
- WINTER / SUMMER switch
- Possibility of setting to partial power in heating mode
- Electronic ignition and control of all functions
- Integrated switching module for eBus interface
- ATTENTION! A set of service taps is not included in the scope of supply and must be purchased separately (article 0010040214)
Installation options
- Heating and built-in hot water supply
- Suitable for residential buildings and apartments under reconstruction and under construction, where it is not possible to install a conventional chimney
- Possibility of installation in a residential area
- Minimum side clearance required is 10 mm, all nodes are accessible from the front
NOT USED IN CASCADE INSTALLATIONSTurbocharged boiler
Depending on the design solution of the boiler room, it allows organizing an air supply and smoke exhaust system through the wall.
Atmospheric boilerThe boiler uses air taken from the room for combustion and requires a classic chimney for the natural removal of combustion products.