Description of Logamatic MM100 functions

Module for use in the EMS plus control system.Control via Buderus RC300 or RC200 control panel.Control of a heating circuit with or without mixer (heating circuit pump or, if necessary, mixer) or direct heating circuit (without mixer), e.g. ventilation circuit, external heat demand via potential-free contact.Control of the first hot water tank (alternative to control of hot water preparation via boiler), for example, control of daily hot water heating up to 60°C.Alternative control of a second hot water tank (requires additional function module MM100 for hot water control), including connection of a second charging pump, a second circulation pump, a second hot water sensor and setting an individual time program.Possibility to connect a hydraulic separator temperature sensor.Linked to a Buderus Logamatic RC300 or RC200 control panel for room temperature control, maintaining the room temperature or reducing the room temperature at night.Possibility to connect a temperature limiter (or STB) for underfloor heating.Possibility to connect an electronically controlled heating pump.
 

Special design considerations MM100
 

  • In combination with the RC300 control panel, a maximum of 6 Buderus MM100 function modules can be installed per heating system (4 for heating circuit control + 2 for DHW heating control).
  • In combination with the RC200 control panel, a maximum of 1 Buderus MM100 module can be installed per heating system.
  • Cannot be combined with MM10, SM10, WM10 function modules and RC25, RC35 control units.